PVI 1800 |
PVI 2500 |
| DC INPUT |
| Absolute Maximum Input Voltage |
400 VDC |
| MPPT Input Voltage Range |
125-350 VDC |
| Maximum Operating Input Current |
11 A |
15 A |
| AC OUTPUT |
| Nominal Output Voltage |
208 or 240 VAC, 1-Ph |
| AC Voltage Range (Standard) |
-12%/+10% |
| Continuous Output Power (280/240 VAC) |
1800W |
2500W |
Continuous Output Current (208 VAC) (240 VAC) |
8.7 A 7.5 A |
12 A 10.4 A |
| Maximum Backfeed Current |
0 A |
| Nominal Output Frequency |
59.3-60.5 Hz |
| Power Factor |
Unity, >0.99 |
| Total Harmonic Distortion (THD) |
<4% |
| Efficiency |
| Peak Efficiency (208/240 VAC) |
94.5% |
94.5% |
CEC Efficiency (208 VAC) (240 VAC) |
92.5% 92.5% |
92.0% 93.0% |
Tare Loss (208 VAC) (240 VAC) |
0.26 W 0.14 W |
0.10 W 0.32 W |
| Temperature |
| Ambient Temp. (full power) |
-13°F to +131°F (-25°C to +55°C) |
| Storage Temperature Range |
-13°F to +131°F (-25°C to +55°C) |
| Relative Humidity (non-condensing) |
5-95% |
| Monitoring Options |
| Web-based Monitoring (Inverter Direct) |
SolrenView |
| Revenue Grade Monitoring |
External |
| Third Party Compatibility |
Standard via RS232/RS485 |
Testing & Certifications
|
| Safety Listings & Certifications |
UL 1741/IEEE 1547, IEEE 62.41.2 C1 & C3, FCC part 15 A & B |
| Testing Agency |
TUV |
| Warranty
|
| Standard |
5 year |
| Optional |
10 year |
| Enclosure
|
| Transformer |
Standard, fully-integrated (internal) |
| AC/DC Disconnects |
Optional with integrated panel |
| Dimensions (H x W x D) |
18.5 in. x 13.1 in. x 5.6 in. (470 mm x 333 mm x 143 mm) |
23.6 in. x 13.1 in. x 5.6 in. (600 mm x 333 mm x 143 mm) |
| Weight |
34.1 lbs (15.5 kg) |
36.3 lbs (16.5 kg) |
| Enclosure Rating |
NEMA 4X |
| Enclosure Finish |
Anodized aluminum |